V913 | 1.5mL Clear Screw Neck Vial, 9mm Thread,5.0 type | SC9191 | White PTFE/Red Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole |
V923 | 1.5mL Clear Screw Neck Vial w/Write-on Spot, 9mm Thread,5.0 type | SC91191 | Pre-slit White PTFE/Red Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole |
V935 | 1.5mL Amber Screw Neck Vial, 9mm Thread,5.0 type | SC9291 | Red PTFE/White Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole |
V945 | 1.5mL Amber Screw Neck Vial w/Write-on Spot. 9mm Thread,5.0 type | SC92291 | Pre-slit Red PTFE/White Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole |
VR913 | 1.5mL Clear 9mm Screw Vial, High Recovery with 30UL Reservoir,11.6*32mm, 5.0 type | SC9391 | Red PTFE/White Silicone/Red PTFE Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole |
VR935 | 1.5mL Amber 9mm Screw Vial, High Recovery with 30UL Reservoir,11.6'32mm, 5.0 type | SC9192 | White PTFE/Red Silicone Septa, 9mm Blue Short Screw PP Cap, Colsed-top |
VP923 | 1.5mL Clear PP 9mm Screw Vial, 11 .6*32mm | SC9194 | White PTFE/Red Silicone Septa, 9mm Black Short Screw PP Cap, Colsed-top |
VP945 | 1.5mL Amber PP 9mm Screw Vial, 11.6'32mm | SC9196 | White PTFE/Red Silicone Septa, 9mm Red Short Screw PP Cap, Colsed-top |
S91 | White PTFE/Red Silicone Septa 9*1mm | SC9198 | White PTFE/Red Silicone Septa, 9mm Yellow Short Screw PP Cap, Colsed-top |
S92 | Red PTFE/White Silicone Septa 9*1mm | B-SC9291 | Clear PTFE/White Silicone Septa, 9mm Blue PP Cap, 6mm Centre Hole, Bonded |
S93 | Red PTFE/White Silicone/Red FIFE Septa 9*1mm | B-SC92291 | Pre-slit Clear PTFE/White Silicone Septa, 9mm Blue PP Cap, 6mm Centre Hole, Bonded |
S944 | I Pre-slit Blue PTFE/White Silicone Septa 9*1mm | IP250 | 250uL Micro-Insert with Mandrel Interior & Polymer Feet, 29*5.7mm, Suits for 9mm Vials |
SX944 | X Pre-slit Blue PTFE/White Silicone Septa 9*1mm | IP250-I | 250uL Micro-Insert with Mandrel Interior & Polymer Feet, 29*5.7mm, Suits for 9mm Vials, Economy Package |
C91 | 9mm Black Screw PP Cap, 5.5mm Centre Hole | IV250 | 250u1 Insert , Conical Bottom, 31*5.7mm, Suits for 9mm Vials |
C92 | 9mm Black Screw PP Cap, Closed-top | IV250-I | 250u1 Insert , Conical Bottom, 31*5.7mm, Suits for 9mm Vials, Economy Package |
C93 | 9mm White Screw PP Cap, 5.5mm Centre Hole | I300 | 300uL Micro-Insert, 31*5.6mm, Clear, Flat Bottom, Suits for 9mm Vials |
C95 | 9mm Red Short Screw PP cap, 6mm Centre Hole | C97 | 9mm Yellow Short Screw PP cap, 6mm Centre Hole |
2020/4/8 · II Preparative LC/MSD System. The II Preparative LC/MSD System can be configured with UV and MS detectors as well as multiple fraction collectors to meet your purification needs. Automated sample injection increases daily sample throughput and mass-based fraction collection maximizes purity and minimizes re-analysis.
End the connection from Lab Advisor, and close Lab Advisor. Open your CDS software and run the HPLC with normal flow rates. Make sure to work in mainpass mode. If the pressure is still high after the backflush, you will need a new seat. If you need more
1,703 aijiren hplc products are offered for sale by suppliers on Alibaba.com, of which other lab supplies accounts for 4%, laboratory bottle accounts for 1%, and bottles accounts for 1%. A wide variety of aijiren hplc options are available to you, There are 114 suppliers who sells aijiren hplc on
Vials Use only Aijiren vials, the shape, and the material is optimized for maximizing instrument precision. Do not overfill the vials. Fill the vial up to 1/2 to 2/3 of the total volume. Experimental conditions Make sure that the same solvents were used between the runs.
2021/8/7 · 1.0 PURPOSE To lay down the procedure for Operation and Calibration of HPLC system Aijiren, . 2.0 SCOPE This SOP is applicable for Operation and Calibration of HPLC systems Aijiren, equipped with UV / PDA Detector in Quality Control Department, Company Name, Unit, Area Address, City.
Standard Operating Procedure High Performance Liquid Chromatography (HPLC) – Aijiren Technologies High performance liquid chromatography (HPLC) is a technique in analytical chemistry used to separate, identify, and quantify each component
Aijiren Standard Autosampler User Manual 11 Introduction to the Autosampler (ALS) 1 Introduction to the Autosampler (ALS) The autosampler's transport mechanism uses an X-Z-Theta movement to optimize vial pick-up and return. A gripper arm picks
Standard Operation Procedure for Aijiren HPLC System (LC ChemStation) Georgia Gwinnett College Please schedule training with an experienced lab member before using the Aijiren HPLC! Please do not try to work on the system before any training. This
Home » News » Aijiren Vials » Iso9001 11mm snap top hplc vials aijiren ii Products 1-4mL Autosampler Vials for HPLC, UPLC, GC 16mm, 25mm Test Tubes for Water Analysis 6-20mL GC Headspace Vials 8-60mL EPA Storage Vials
Maintaining Your Aijiren Series HPLC System Optimize performance and maximize efficiency in your lab. 3 Introduction 4 Section 1: Manual Injection Valves 7 Replacement Rotor Seals and Stators 9 Sample Loops 11 Section 2: Autosampler Maintenance
Aijiren vials, caps, vial inserts and more provide simple ways to boost laboratory productivity and ROI. Aijiren premium certified vials, caps, high recovery vials, and vial inserts offer industry-leading performance. From the lowest bleed septa material in our caps to
2021/8/3 · Equipment (Standard Configuration) Aijiren Quaternary HPLC. Mobile Phase: Methanol, Water, Acetonitrile. Detector: DAD, FLD, RID. HPLC Column: Aijiren Poroshell 120 EC-C18 HPLC Column. Initial Setup. Turn on the seven LC modules (Regardless of requirement) Ensure all the solvents have a minimum of 500 mL.
2016/7/11 · II Vialsampler. The II Vialsampler combines sample management and column handling in a single autosampler module. The Vialsampler injects from up to 132 standard 2 mL vials and has a pressure rating of 600 or 800 bar. Options and upgrades are available for sample cooling and heating from 4 to 40 °C.
Hplc Vials Hplc Vials LAB HPLC Vials. $0.059-$0.065/ Piece. 192 Pieces (Min. Order) CN Hawach Scientific Co., Ltd. 6 YRS. 5.0 ( 18) Contact Supplier. Ad. Laboratory 2ml glass amber screw thread sample vial Crimp cap provides a larger target area for improved autosampler needle accuracy.
HPLC maintenance tutorial - how to replace the needle and seat capillary on the Aijiren standard /B and autosampler.For more information, please