Vial size is 12 x 32 mm with a writing patch on the side. Use with any HPLC autosampler rack for 1.5mL (2mL) vials. Can also be used in the AOC autosamplers for Shimadzu GCs. Adjust needle stroke 3-4 mm less than for a flat bottom 1.5 mL vial to prevent damage to the needle. Price: $132.00 In stock Quantity:
9mm 2ml PP Screw Top Vial for SHIMADZU. The 2ml HPLC PP Vial and Cap provided by Aijiren is usually 9mm in diameter, because the 9mm HPLC Vial can match most HPLC Autosamplers on the market. The specification of the 2ml HPLC PP vial is 12x32mm, the opening is increased by 40%, and the standard capacity is 1.5ml. The Cap of the 2ml hplc pp vial
Gas Chromatography. Gas Chromatograph-Mass Spectrometry. Columns, Reagents and Consumables. Software & Informatics. MALDI-Based Instruments and Solutions. Molecular Spectroscopy. Elemental Analysis. Life Science Lab Instruments. Material Testing.
2ml snap micro vials for hplc system Shimadzu Free sample 2ml HPLC vial insert price micro vial hplc price China CHROMATOGRAPHY VIALS. Free Call1800 723 405.au 5 2ml Snap Top Vials Caps 1ml Shell Vials ˜ 11mm,2ml,snap neck. ˜ Widely used in HPLC appliions,universally usable vials for most
These chromatography vials provide reliable performance regardless of the manufacturer while maintaining high productivity. Provided is a table that displays the many vial types Aijiren offers and the autosampler models they are compatible with. Explore the vast array of autosampler vials Aijiren has to offer.
Shimadzu now offer standard 2mL (1.5mL) vials designed for mutli vendors autosampler. Shimadzu Vial Packs Part Number Description Colour 226-50512-00 Vial Kit , Standard, 2ml Clear glass, 9mm, includes vial, bonded Si/PTFE cap and septa, pk 100 Clear 226-50512-10 Vial Kit , Standard ,2ml Clear glass, 9mm, includes vial, bonded Si/PTFE cap and septa, pk 1000 Clear 226-50513-00
Vials & Caps | SHIMADZU EUROPA Vials & Caps Product Lineup 1.5 ml Kits, Vials and Caps 1.5 ml standard vials and kits for LC/LC-MS and GC/GC-MS. Screw, crimp, snap ring vials and caps. GC/MS & LC/MS Certified Vials 1.5 ml kits with certified reduced adsorption of basic substances TORAST-H Vials
Jan 24, 2023 · The total-volume injection SIL-30AC autosampler features a pressure tolerance of 130 MPa as well as the world’s fastest sample injection (10 seconds), which dramatically reduces the total cycle time. It includes auto pretreatment and overlapping functions as standard, and an optional loop-injection method configuration to minimize delay volume.
Three Features of the Shimadzu LabTotal Vial This improves quantitative accuracy in the analysis of trace basic compounds. This product can be used as a vial for high-sensitivity analysis in conventional LC and in LC/MS analysis. This shortens the time needed for sample preparation and reduces human error. Reduced Adsorption of Basic Substances
Shimadzu Certified Vials are tested for: Dimensional accuracy. Glass cleanliness using HPLC and MS (tested and certified contaminant free) Septa cleanliness and sealing test. Glass quality. For guaranteed performance of your instrument, (whatever the brand), move to Shimadzu Certified Vials.
HPLC systems are currently used in a wide variety of fields. Higher reliability in analysis data and higher efficiency in total analysis workflow are required for faster development of new drugs, for better food safety, and for meeting higher standards in environmental regulations.
TORAST-H Vial Series : SHIMADZU (Shimadzu Corporation) Shimadzu Original Low Absorption Glass Vial Glass, the material of vials, contains metal oxides. Oxides of metals have a high ionizing tendency to be Si-O-M (metal silanolate), which may cause ionic adsorption with basic compounds in the sample.
Polypropylene 96-well MTP. Square well, round bottom, approx. 2mL volume. Pre-slit PTFE/silcone mat (12 or 72/pk) is available to reseal wells and protect labile samples. Use with the SIL-40, LC-40 Plate Changer, Rack Changer or the appropriate MTP rack for the SIL-HTa/c, SIL-20A/AC, SIL-30AC, SIL-30ACMP, LC-2010a/c, LC-2030, and LC-2040.
This phenomenon of ionic adsorption is analogous to the phenomenon of peak tailing and increased retention of basic compounds caused by residual silanol in an HPLC column. For plastic containers, the only adsorption caused by the container material (high molecular weight polymers) is hydrophobic adsorption.
Optimal needle penetration. Compatible with Shimadzu™ Prominence HPLC Systems. Compatible with Nexera X2 UHPLC/HPLC Systems. Convenience kits come complete with vials and closures. Featuring a soft durometer silicone septa for optimal needle penetration and recommended for Shimadzu Autosamplers.