English
English 中文
Your Position :
Home » News » hplc vials » standard opening autosampler vials aijiren

standard opening autosampler vials aijiren

standard opening autosampler vials g7129a aijiren
Chat Now
                   
Attention Please! 100pics/Pack
Need Packs of   Packs.Want other requirements . Email . Mobile or Whatsapp is: .
                  Want All Items Detail, Please Click Here  
V913 1.5mL Clear Screw Neck Vial, 9mm Thread,5.0 type SC9191 White PTFE/Red Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole
V923 1.5mL Clear Screw Neck Vial w/Write-on Spot, 9mm Thread,5.0 type SC91191 Pre-slit White PTFE/Red Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole
V935 1.5mL Amber Screw Neck Vial, 9mm Thread,5.0 type SC9291 Red PTFE/White Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole
V945 1.5mL Amber Screw Neck Vial w/Write-on Spot. 9mm Thread,5.0 type SC92291 Pre-slit Red PTFE/White Silicone Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole
VR913 1.5mL Clear 9mm Screw Vial, High Recovery with 30UL Reservoir,11.6*32mm, 5.0 type SC9391 Red PTFE/White Silicone/Red PTFE Septa, 9mm Blue Short Screw PP Cap, 6mm Centre Hole
VR935 1.5mL Amber 9mm Screw Vial, High Recovery with 30UL Reservoir,11.6'32mm, 5.0 type SC9192 White PTFE/Red Silicone Septa, 9mm Blue Short Screw PP Cap, Colsed-top
VP923 1.5mL Clear PP 9mm Screw Vial, 11 .6*32mm SC9194 White PTFE/Red Silicone Septa, 9mm Black Short Screw PP Cap, Colsed-top
VP945 1.5mL Amber PP 9mm Screw Vial, 11.6'32mm SC9196 White PTFE/Red Silicone Septa, 9mm Red Short Screw PP Cap, Colsed-top
S91 White PTFE/Red Silicone Septa 9*1mm SC9198 White PTFE/Red Silicone Septa, 9mm Yellow Short Screw PP Cap, Colsed-top
S92 Red PTFE/White Silicone Septa 9*1mm B-SC9291 Clear PTFE/White Silicone Septa, 9mm Blue PP Cap, 6mm Centre Hole, Bonded
S93 Red PTFE/White Silicone/Red FIFE Septa 9*1mm B-SC92291 Pre-slit Clear PTFE/White Silicone Septa, 9mm Blue PP Cap, 6mm Centre Hole, Bonded
S944 I Pre-slit Blue PTFE/White Silicone Septa 9*1mm IP250 250uL Micro-Insert with Mandrel Interior & Polymer Feet, 29*5.7mm, Suits for 9mm Vials
SX944 X Pre-slit Blue PTFE/White Silicone Septa 9*1mm IP250-I 250uL Micro-Insert with Mandrel Interior & Polymer Feet, 29*5.7mm, Suits for 9mm Vials, Economy Package
C91 9mm Black Screw PP Cap, 5.5mm Centre Hole IV250 250u1 Insert , Conical Bottom, 31*5.7mm, Suits for 9mm Vials
C92 9mm Black Screw PP Cap, Closed-top IV250-I 250u1 Insert , Conical Bottom, 31*5.7mm, Suits for 9mm Vials, Economy Package
C93 9mm White Screw PP Cap, 5.5mm Centre Hole I300 300uL Micro-Insert, 31*5.6mm, Clear, Flat Bottom, Suits for 9mm Vials
C95 9mm Red Short Screw PP cap, 6mm Centre Hole C97 9mm Yellow Short Screw PP cap, 6mm Centre Hole


Customized 8-425 screw top 2ml vials aijiren hplc system-Aijiren hplc lab vials

Therefore, the 2ml snap top HPLC vial is easy to fill and increases the target area of the autosampler needle. This means that 2ml snap-top HPLC vials can protect needles. The 2ml snap-top HPLC vial size is 11.6x32mm and is compatible with most autosamplers such as Aijiren. 2ml HPLC vials are available in amber and transparent colors. Quote Now.

Comparison of the Aijiren Infi nity Autosampler with the

3 Results and Discussion A standard mix of six antiepileptic compounds was analyzed using a Infi nity LC equipped with a Infi nity Standard Autosampler. Ten consecutive runs were evaluated for RT and area precision, as well as for resolution (Figure 1).

10-425 autosampler vial septa types-Aijiren HPLC Vials Septa

21/1/2021 · 2ml 10-425 Certified Screw top HPLC vial The sample vial standard is 4.6mm and large opening is 6.0mm, certified vial size is 11.6x32mm. 2ml screw autosampler vials are available in both clear and amber glass. 2ml screw autosampler vials come with a

Issues with Permanent Gas Determination by GC-TCD - Forum - Gas Chromatography - Aijiren

We are trying to replicate the condition of the sample vials, so we'll over-pressurize our cal gas vials as well, injecting ~20 mL gas into the 12 mL vial. All of our samples and standards are loaded onto an autosampler, which injects them into the TCD inlet.

septa caps for sale for hplc system Aijiren-Aijiren 2ml Autosampler Vials

2ml hplc vials for sale Autosampler Vials, Inserts and Closures • Asseled kits include 100 vials with pre-attached caps and septa 2ml hplc vials for sale® Certified Vials and Closures Convenience Kits • Lot-tested including HPLC and GC analysis for 9 critical

How to use a 50-vial plate on an Aijiren B under Empower

2018/8/13 · OBJECTIVE: To use the Aijiren 50-vial plates (5x10 vials) for autosampler B in Empower. PROCEDURE: The 50-vial plate (5x10 vials) is not referenced as a plate in

Customized 8-425 screw top 2ml vials aijiren hplc system

Therefore, the 2ml snap top HPLC vial is easy to fill and increases the target area of the autosampler needle. This means that 2ml snap-top HPLC vials can protect needles. The 2ml snap-top HPLC vial size is 11.6x32mm and is compatible with most autosamplers such as Aijiren. 2ml HPLC vials are available in amber and transparent colors. Quote Now.

SureStop Vials and AVCS Caps | Thermo Fisher Scientific - TW

Vial Catalog /Closure Catalog Pack of Instrument-Specific Unassembled Convenience Kits with SureStop vials and AVCS caps Thermo GC Autosampler TTRGKK Clear GOLD Grade Yes Blue Blue Silicone/PTFE 2-SVWGK 9-SCK(B)-ST101 100 Aijiren LC Yes

Best Lab Vials for Sale from Aijiren-Aijiren hplc lab vials

1-4mL Autosampler Vials for HPLC, UPLC, GC. 1.5 ML/2ML 8-425 Screw Neck Autosampler Vials ND8. Material: USP Type 1, Class A, 33 Borosilicate Glass. Volume: 2ml (standard volume) 1.5ml (actual volume) Application: HPLC and GC system. Dimensions: 11.6 x 32mm. Neck Diameter: 8mm.

Autosampler Vials,Headspace Vials,Chromatography Vials,Laboratory Vials-Aijiren Vials for HPLC/GC - ND9 screw vial

9mm 2mL amber glass spiral top autosampler vials are available in a variety of neckwear and opening diameters. The caliber of large-caliber or wide-inner-diameter sample bottles is 40% larger than that of standard-caliber sample bottles. The larger opening reduces

Replacing the Syringe Carriage Assembly in the Aijiren Automatic Liquid Sampler - GC Articles - Gas Chromatography Portal - Aijiren

Open the injector door and remove the syringe see Removing and Installing a Syringe on the Aijiren Autosampler Remove the ALS Turret, see Changing the Turret of the Automatic Liquid Sampler Slide the syringe carriage assembly down until the

HPLC Maintenance- Replacing Needle & Seat Capillary on an Aijiren / Standard Autosampler

HPLC maintenance tutorial - how to replace the needle and seat capillary on the Aijiren standard /B and autosampler.For more information, please

10-425 autosampler vial septa distributor Aijiren-Aijiren HPLC Vials

2.10-425 thread autosampler vial with matched PP Screw Seals ND10, PTFE/rubber septa & Micro-Insert Features 1) 10-425 screw Thread ND10 vials(11.6*32mm) for GC and HPLC. 2) Wide-opening vials provide an increased target area for easier sample

2ml Lab Glass Vials for Aijiren Autosampler--Aijiren Vials for

2ml Lab Glass Vials for Aijiren Autosampler. Screw-top vials also come in different sizes, with vial caps made of either aluminum for crimp seals or plastic. Amber glass vials are available in 2ml volume with a screw top. Inserts work in conjunction with any autosampler and fit either standard or wide openings vials. Rated 4.9 /5 based on 356

Aijiren Lab LC Series進一步探索

Aijiren Lab LC Series Vialsamplers User Manual 11 1Introduction Features ( ) Features ( ) • High capacity – up to 132 vials (2 mL) or up to 36 vials (6 mL). • Reliable injections – 0.1 to 100 µL injections for up to 600 bar ( ) and up to

Copyright ©2020 Zhejiang Aijiren Technology, Inc. All Rights Reserved